Most "plumbing rough-in checklist" templates are phase trackers wearing a different name. They start at the underground, run through top-out and finish at trim, and they answer the question "where is this job up to". That is a useful document, and CloseCrew ships one — the new construction plumbing checklist, which carries the full IPC 312 test table across five phases. It is not this document.
This sheet answers a narrower and more urgent question: is there anything here that must not be covered yet. It is a single-event walk, worked in the hour before the inspector arrives and before the insulator and the drywall crew turn every mistake into a demolition job. So its spine is not the build sequence — it is the set of things that block concealment. What must still be visible. What the framer’s saw already did to the studs your pipe runs through. Whether a plate went on where the pipe sits close to the stud face. Whether the gauge is still holding, and whether the inspector can read it from the floor.
The framing section is the part no competitor template has, because it needs arithmetic rather than a tick box. IRC R602.6 and R502.8.1 express their limits as fractions of the member’s depth, and the member’s depth is its actual dressed dimension, not its nominal name. A 2x4 is 3-1/2 inches, so a bearing-wall stud takes a 7/8 inch notch and no more. A 2x10 joist is 9-1/4 inches, so a one-third-depth bore is 3.083 inches and a one-sixth-depth notch is 1.542. Enter the depth you measured and the sheet returns the number for that member, then scores what you cut against it. A bore over 40 percent of the depth in a bearing or exterior wall additionally demands the stud be doubled, and the sheet asks for that confirmation rather than quietly passing it.
The protection rule is the one that trips people who work under both codes. IPC 305.6 and NEC 300.4 agree on the trigger — under 1-1/4 inches from the nearest edge of the framing member — but they do not agree on the plate. The IPC asks for 0.0575 inch, which is No. 16 gage. The NEC asks for at least 1/16 inch, which is 0.0625. A plumber’s stud guard is five thousandths of an inch shy of the electrical minimum. This sheet prints the figure for the trade it is scoped to and never averages the two.
Values here are from the 2021 International Plumbing Code and the 2021 International Residential Code. Adoption is a local decision, editions in force range from 2009 to 2024, and several states use the Uniform Plumbing Code or a code of their own. The sheet records the authority having jurisdiction and the edition it enforces rather than pretending there is a national answer, and every measurement prints the section it was judged against so a reviewer can check the reasoning rather than the result.