Change Out Checklist
HVAC · System Change Out
Items
0
Complete
Pass / fail
0 / 0
Blocking open
0/0
Sign-off
Not started
1Job & technicianWho did the change-out, on what date, under which permit.CO-2026-001
Certification & inspectionEPA 608 #, inspection date
EPA Section 608 technician certification number. Recovery before the system is opened is a federal requirement, and the certification is what backs the entry on this sheet.
2Contractor & customerAppears at the top of the finished checklist.Not set
3EquipmentThe system type, what it is charged with, and the static pressure it is rated for.Split system A/C · R-454B · 0.5 in. w.c.
New residential systems ship with R-454B or R-32 — A2L, mildly flammable. That changes the job: A2L-rated gauges, recovery machine and leak detector, a refrigerant detection system on the equipment where UL 60335-2-40 requires one, and a line set that is either new or flushed and nitrogen purged with the manufacturer's approval. Setting this to a non-A2L refrigerant drops the A2L-only items from the checklist you can add. R-410A units built or imported before 1 January 2025 may still be installed from existing inventory under the EPA's 2026 rule, except where a state has kept the original deadline.
The equipment's rated total external static pressure, from the nameplate or the installation manual. Both static-pressure items on the checklist are graded against this number, so a unit rated 0.8 in. w.c. is judged at 0.8 — not at the 0.5 in. w.c. most residential air handlers carry. Above the rating the blower cannot deliver rated airflow, and new equipment will not fix an existing duct problem.
Old & new unit, line setFor the permit and the warranty file
AHRI certifies split-system performance for the outdoor and indoor combination, not for either unit on its own. The Certified Reference Number for the pairing is what rebate programs, tax credits and warranty claims are checked against.
4Change-out checklistAdd the items this job needs, then tap a result on each one.Nothing checked
Pre-install
Tap Pass, Fail or N/A. Three items grade themselves from the reading you enter: evacuation against 500 microns, and the two static-pressure items against the rated ESP recorded on this sheet. Change the result on a graded row and your call stands — you have seen the equipment and the gauge has not. Set the row back to Open to hand grading back to the measurement.
Nothing on the sheet yet. Open + Add item for the standard change-out steps, phase by phase, or type your own.
A blocking item holds the sign-off. While any blocking item is still open or failed the checklist reads "Not ready to sign off", no matter how high the completion percentage climbs. Which items block is set by the checklist itself — a company decides that, not the technician in the attic. Mark one N/A when it genuinely does not apply, such as gas piping on an all-electric change-out.